We are fully equipped for the complete testing of these products, including washing, visual inspection, electrical testing and documentation.
Hot Sticks are cleaned, waxed and wet tested in accordance to current standards.
All rubber protected equipment tested by Crane Edge, LLC undergoes this rigorous sequence to ensure that your employees are always using safe equipment.
Contact us today and schedule for onsite or at our facility! Contact Billy Conway: 304-942-9315 or billy@craneedge.com
ANSI A92.2
5.3.4 Periodic Electrical Test.
Each insulating aerial device shall be periodically electrically tested in accordance with Section 5.4.3 to verify the dielectric resistivity and detect conductivity changes in its insulating sections.
(c) After repair or replacement of any com-ponent that crosses the insulating system(s),or the repair or replacement of an insulating component(s) (e.g., hoses, leveling rods, boom coating, etc.), the unit shall be dielectrically tested in accordance with section 5.4.3;
1910.67(c)(3)
"Electrical tests." Electrical tests shall be made in conformance with the requirements of ANSI A92.2 - 1969, Section 5. However, equivalent DC voltage tests may be used in lieu of the AC voltage test specified in A92.2 - 1969. DC voltage tests which are approved by the equipment manufacturer or equivalent entity shall be considered an equivalent test for the purpose of this paragraph (c)(3).
Aerial lifts may be "field modified" for uses other than those intended by the manufacturer provided the modification has been certified in writing by the manufacturer or by any other equivalent entity, such as a nationally recognized testing laboratory, to be in conformity with all applicable provisions of ANSI A92.2-1969 and this section and to be at least as safe as the equipment was before modification.
The insulated portion of an aerial lift shall not be altered in any manner that might reduce its insulating value.
dielectric testing up to 100kV as specified by ANSI standards. The dielectric test verifies the electrical insulating strength in the FRP upper and lower booms, bucket, liners, FRP extensions on digger derricks, tool circuits, and upper control system.
OPTIONAL TESTS
Bucket liners
DIELECTRIC TESTING
Line (ground) Jumpers.
Line hoses.
Gloves.
Hot Sticks
Covers/Blankets
Contact us today and schedule for onsite or at our facility!